Why coordination tools matter in a small-building model
As your model grows, small placement errors compound: partitions drift off grids, repeated room layouts become inconsistent, and changes ripple unpredictably. Coordination tools help you keep geometry intentional and editable. In this chapter you’ll learn how to use Align, temporary dimensions, constraints/locks, Mirror, and Array (carefully), plus when Groups are worth it. You’ll also get a beginner-friendly awareness of Copy/Monitor so you recognize it when coordination with other models becomes relevant.
Align: the fastest way to make elements truly line up
What Align does (and what it does not)
Align moves an element so a chosen face/edge/centerline matches a reference face/edge/centerline. It is more reliable than dragging because it snaps to actual geometry and can optionally create a lock (constraint) between the two.
- Use Align to: align partition faces to grid lines, align door/window centers to reference planes, align fixture edges to wall faces.
- Avoid Align as a “fix everything” tool: if the element is wrong because its host or sketch is wrong, aligning may hide the real issue.
Step-by-step: Align a wall face to a grid
- Go to a plan view where you can see the grid and the wall clearly.
- Start Modify > Align (shortcut:
AL). - Pick the reference first: click the grid line (or a reference plane).
- Pick the target second: hover the wall until you see the correct face highlight (finish face vs. centerline), then click.
- If you want the relationship to stay fixed, click the small lock icon that appears (only lock when you are confident the relationship should never drift).
Common beginner pitfalls with Align
- Aligning to the wrong wall reference: Revit may highlight the wall centerline when you intended the finish face. Zoom in and watch the highlight carefully.
- Locking too early: locking everything can make later edits fail or create warnings. Use locks sparingly and intentionally.
- Aligning hosted elements without checking the host: if a door looks off, the wall may be off. Align the wall first, then hosted elements.
Temporary dimensions: quick, accurate edits without adding permanent constraints
What temporary dimensions are
When you select an element (like a wall), Revit shows temporary dimensions to nearby references (grids, walls, etc.). These are not permanent annotations; they are an editing aid. You can type values directly into them to place elements precisely.
Step-by-step: Use temporary dimensions to set a partition offset
- Select the interior wall.
- Find the temporary dimension that references the grid (or another wall).
- Click the dimension value and type the desired distance (for example
1200). - Press
Enterto apply.
Tips for reliable temporary-dimension editing
- Change the witness references if needed: drag the small blue witness grips to a different reference (e.g., from wall face to wall centerline) before typing a value.
- Prefer dimensions over dragging when accuracy matters (bathrooms, corridors, tight clearances).
Constraints and locking: keep intent, avoid over-constraint
Concept: “Constrain what must remain true”
A constraint is a rule that forces a relationship to remain true during edits (e.g., a wall face stays aligned to a grid). Constraints are powerful but can cause warnings or prevent changes if you overuse them.
Responsible locking guidelines
- Lock to primary references (grids, key reference planes) when the design intent is stable.
- Avoid locking to “temporary” geometry (like another partition that may move later).
- Lock sparingly in early design; increase constraints as the layout stabilizes.
- When something won’t move, check for locks before forcing edits.
Where locks commonly appear
- Align tool lock icon (after aligning).
- Some sketch-based relationships (e.g., aligned sketch lines) depending on how you created them.
Mirror: symmetry without rework (but watch handed elements)
What Mirror is good for
Mirror duplicates or flips elements across an axis. It’s useful for symmetric layouts (paired rooms, mirrored partitions) and can save time when the mirrored condition is truly symmetrical.
- Listen to the audio with the screen off.
- Earn a certificate upon completion.
- Over 5000 courses for you to explore!
Download the app
Step-by-step: Mirror a set of interior partitions
- Select the elements to mirror (use a window selection carefully).
- Start Modify > Mirror and choose Pick Axis (or use an existing reference plane as the axis).
- Click the axis (grid line or reference plane).
- Decide whether to keep the original: toggle Copy on (to create a mirrored copy) or off (to flip in place).
Mirror cautions
- Handed components: some families have left/right orientation. After mirroring, verify door swings, plumbing fixture orientation, and clearances.
- Hosted elements: mirrored hosted elements may behave differently if hosts are not symmetric or if constraints exist.
Array: repeated elements with caution
Concept: arrays can create rigid patterns
Array creates multiple copies in a line or around a center. It can be helpful for repeated items (like evenly spaced columns or fixtures), but arrays can become hard to edit if the design changes. Use arrays when repetition is truly regular and likely to remain so.
Step-by-step: Create a simple linear array (safe workflow)
- Select a simple element that is safe to repeat (e.g., a generic model placeholder or a fixture in a long restroom).
- Start Modify > Array.
- Choose Linear, set the direction by picking two points.
- Set the number of instances.
- Prefer “Move To” with a known spacing rather than eyeballing the end point.
- If you don’t need a live relationship, consider turning off Group and Associate (when available) so the result is easier to edit as individual items.
Array cautions for beginners
- Associated arrays can be difficult to modify later without breaking the pattern.
- Arrays + constraints can multiply warnings if other locked relationships exist.
- If you find yourself fighting the array, it’s often faster to delete it and place items with dimensions or simple copy.
Groups: when repeated layouts are worth grouping (and when they are not)
Concept: a Group is a reusable set of model elements
A Model Group lets you repeat a layout (walls, doors, fixtures, etc.) and keep instances coordinated: edit the group once, and all instances update. This is useful for repeated units (identical bathrooms, hotel rooms, apartment modules) in small buildings.
When Groups are a good idea
- You have truly repeated layouts that should stay identical.
- The repeated set is self-contained (mostly internal to the room/module).
- You expect multiple instances (more than two is usually where it starts paying off).
Risks and limitations (why groups can get messy)
- Group edit complexity: editing a group can be confusing because you’re temporarily in a special editing mode.
- Constraints and hosted relationships inside groups can create warnings when placed in different contexts.
- “One-off” variations are awkward: if one bathroom needs a slightly different wall or fixture, you may need a second group type or to ungroup (breaking coordination).
- Over-grouping (grouping large portions of the building) can make the model brittle and slow to adjust.
Step-by-step: Create a bathroom layout group (optional)
- In plan view, select only the elements that define the repeated bathroom layout (typical set: interior partitions, door, fixtures, accessories).
- Click Create Group (Modify tab) and choose Model Group.
- Name it clearly, e.g.,
Bath_Standard_01. - Place another instance: use Place Model Group and click to place it in the second location.
- Test an edit: select a group instance, click Edit Group, move a fixture slightly, then Finish. Confirm both bathrooms updated.
Stability tips for groups
- Keep group boundaries tight: avoid including surrounding corridor walls or external references unless they are identical in every location.
- Minimize locks inside groups: use dimensions for placement where possible; lock only what must remain fixed.
- Use clear naming so you can manage types if variations appear later.
Copy/Monitor basics: awareness for coordination (without needing a full collaboration setup)
What Copy/Monitor is (in plain terms)
Copy/Monitor is a coordination feature that helps you copy certain elements (commonly levels and grids) from another model and then monitor them for changes. If the source changes, Revit can flag coordination issues so you can respond intentionally.
In a beginner small-building workflow, you may not be linking consultant models yet. Still, it’s useful to understand the concept because it explains why some projects have “monitored” grids/levels and why changes can trigger warnings.
What it is commonly used for
- Architectural model monitoring structural grids/levels (or vice versa).
- Keeping shared references consistent across disciplines.
What Copy/Monitor is not
- It is not a magic “keep everything coordinated” button.
- It does not automatically resolve conflicts; it reports them so you can decide.
Beginner-safe takeaway
If you ever link another model and see options related to Copy/Monitor, remember: start by monitoring levels and grids only. Avoid monitoring lots of element categories until you understand the impact on warnings and workflows.
Practice tasks (hands-on coordination drills)
Task 1: Align interior partitions to grids (accuracy + intent)
- Pick 3–5 interior partitions that should be aligned to a main grid line or a reference plane.
- Use Align (AL) to align the correct wall face or centerline to the grid.
- Lock only one of these alignments (choose the one that truly must stay fixed).
- Move the grid slightly (or adjust a dimension) and observe what updates and what does not.
- Undo and repeat, this time locking a different relationship, to feel the difference.
Task 2 (optional): Group a repeated bathroom layout and test edits
- Create a small bathroom layout that you can repeat (partitions + door + a few fixtures).
- Create a Model Group from the selection.
- Place a second instance elsewhere.
- Edit the group: move one fixture by a small, dimensioned amount.
- Confirm both instances update. If something breaks, note what element caused it (often constraints/hosts) and simplify the group selection.
Task 3: Stability test—make changes without breaking the model
- Choose an area where you used Align and at least one lock.
- Try these edits one at a time: move a wall, change a dimension value, mirror a small set of elements.
- When an edit fails or behaves unexpectedly, check for: (a) locks created by Align, (b) grouped elements, (c) an array pattern.
- Remove or reduce constraints (unlock) and retry the edit to see how model flexibility changes.
| Tool | Best for | Main risk | Beginner rule of thumb |
|---|---|---|---|
| Align | Precise alignment to grids/planes/faces | Locking the wrong reference | Align first; lock only if intent is stable |
| Temporary dimensions | Fast numeric placement | Editing to the wrong witness reference | Adjust witness grips before typing values |
| Locks/constraints | Protecting key relationships | Over-constraint and warnings | Constrain what must remain true |
| Mirror | Symmetry and paired layouts | Handed components flip unexpectedly | Verify swings/orientation after mirroring |
| Array | Regular repetition | Hard-to-edit associated patterns | Use only when repetition is truly regular |
| Groups | Repeated room modules | Complex edits and brittle relationships | Group small, repeatable, self-contained sets |
| Copy/Monitor | Cross-model reference coordination | Too many monitored items = noise | Start with levels/grids only (awareness) |