Daily operations in access control are about turning policies into repeatable routines. The goal is to reduce “drift” (small shortcuts that become normal) and lower risk by using checklists, clear post orders, and a simple improvement loop. This chapter focuses on how to run a shift consistently—what to verify, when to verify it, and how to capture issues so they get fixed.
1) Start-of-shift checks: set conditions for a controlled day
Start-of-shift checks confirm that your post can operate safely and consistently before the first rush. Treat this as a “go/no-go” inspection: if a critical item fails, you either correct it immediately or escalate and apply a temporary control.
Start-of-shift routine (step-by-step)
- Arrive early enough to inspect (typical target: 10–15 minutes before taking responsibility).
- Review handover notes from the prior shift for open issues (equipment faults, recurring queue spikes, known visitors/contractors, temporary restrictions).
- Perform equipment checks (radios, scanners, computers/tablets, printers, flashlights, body-worn camera if used).
- Confirm credential supplies (badges, lanyards, temporary passes, wristbands, printer stock, ink/toner).
- Verify signage and lane setup (directional signs, “stop here” markers, cones, stanchions, speed limit signs).
- Test barriers and safety devices (gate arms, bollards, turnstiles, intercoms, emergency stop, safety loops/sensors).
- Confirm communications and escalation paths (radio channel, contact list, supervisor availability, maintenance number).
Printable-style checklist: Start-of-shift
START-OF-SHIFT CHECKLIST (ACCESS CONTROL POST) Date: ____ Shift: ____ Officer: ____ Post: ____
A) Communications
[ ] Radio powers on; battery charged/spare available
[ ] Correct channel set; radio check completed
[ ] Emergency contact numbers accessible
B) Screening/Verification Tools
[ ] ID/credential scanner works (test scan)
[ ] Computer/tablet login successful; network OK
[ ] Printer works (test print if applicable)
[ ] Flashlight available; spare batteries
C) Credential Supplies
[ ] Temporary badges/passes count: ____ (min threshold: ____)
[ ] Lanyards/wristbands available
[ ] Printer stock/labels available
D) Physical Post Condition
[ ] Counter/window clean and organized
[ ] Forms/log sheets available (if used)
[ ] Clock/time source accurate (for timestamps)
E) Signage & Traffic Control
[ ] Signs visible and correctly placed
[ ] Cones/stanchions positioned for current lane plan
[ ] “Stop” point clearly marked
F) Barriers & Safety
[ ] Gate/turnstile cycles normally (open/close test)
[ ] Safety sensors/loops functioning
[ ] Emergency stop tested/verified accessible
[ ] Manual override key/device present (if authorized)
G) Exceptions/Temporary Controls (if any)
[ ] Temporary procedure posted/understood (describe): __________
[ ] Supervisor notified of any critical defects
Issues found / actions taken: ____________________________________________Post orders: what they should contain for daily use
Post orders are the “how we run this post” instructions that support consistent daily routines. For daily operations, they should be written so a relief officer can follow them without guessing.
- Post purpose and boundaries: what you control (lanes, doors, docks) and what you do not.
- Operating hours and peak patterns: known rush windows and the standard lane plan for each.
- Minimum equipment and supply levels: the “reorder/escalate” thresholds.
- Barrier operation rules: when barriers may be opened, by whom, and what must be verified first.
- Temporary control options: what to do if scanner is down, printer fails, or a lane must be closed.
- Required checks: start/mid/end-of-shift checklists and where to file them.
2) Mid-shift controls: keep the process from drifting
Mid-shift controls are short, repeatable checks that catch problems early: incomplete logs, creeping shortcuts, equipment degradation, and queue conditions that create pressure to “wave through.” The key is to schedule them (e.g., every 2–3 hours and during/after peak periods) rather than relying on memory.
Mid-shift routine (step-by-step)
- Spot audit a small sample of recent transactions (e.g., last 10 entries) for completeness and consistency.
- Check queue conditions and apply the pre-approved adjustment plan (open an additional lane, switch to a different staging pattern, call for support).
- Verify log completeness (required fields filled, correct timestamps, required attachments captured).
- Re-check critical equipment (radio battery level, scanner responsiveness, printer status).
- Confirm signage and barriers remain correctly positioned after any adjustments.
- Document any deviations and the reason (e.g., “scanner rebooted at 10:14; used manual verification procedure for 6 minutes”).
Printable-style checklist: Mid-shift controls
MID-SHIFT CONTROL CHECKLIST Time: ____ Officer: ____ Post: ____
A) Spot Audit (sample size: ____)
[ ] Required fields complete (names/IDs/vehicle plate if applicable)
[ ] Reason for entry/delivery recorded where required
[ ] Any exceptions documented with reference/approval
B) Queue & Flow
[ ] Current wait estimate: ____ minutes
[ ] Lane plan matches current volume (Y/N)
[ ] Adjustment made (if needed): ______________________________
[ ] Safety maintained (no bypassing barriers; pedestrians controlled)
C) Equipment Health
[ ] Radio battery OK / swapped if low
[ ] Scanner reads consistently; no repeated errors
[ ] Printer/labels OK; supplies above threshold
D) Barrier & Signage
[ ] Gate/turnstile operating normally
[ ] Cones/signs still visible and correctly placed
Notes / issues escalated: ____________________________________________Queue management adjustments: a practical decision guide
| Condition observed | Risk created | Standard adjustment | What to document |
|---|---|---|---|
| Wait times rising rapidly | Pressure to skip steps | Open additional lane or switch to peak lane plan | Time change started; staffing/lane change |
| Vehicles stacking into roadway | Traffic hazard | Move staging point; add cones; call supervisor/traffic support | Hazard noted; controls added; who notified |
| Frequent rework (bad scans, printer jams) | Process slowdown | Swap device, reboot, use approved temporary control | Start/end time of workaround; device ID |
| Confusion about where to stop/line up | Lane jumping, disputes | Reposition signage; assign a “line director” temporarily | What changed; time; observed effect |
3) End-of-shift reconciliation: leave the post “closed out” and ready
End-of-shift reconciliation ensures that controlled items (badges, keys, access devices) are accounted for, unresolved issues are clearly flagged, and the next shift inherits a stable post. This is where small gaps become visible—missing badges, incomplete incident follow-ups, or equipment that “sort of works.”
- Listen to the audio with the screen off.
- Earn a certificate upon completion.
- Over 5000 courses for you to explore!
Download the app
End-of-shift routine (step-by-step)
- Stop and reconcile controlled items before you get rushed by shift change.
- Count and secure badges/passes (issued vs. returned; remaining stock).
- Key control check (keys present, signed in/out correctly, stored in the correct location).
- Review unresolved incidents/issues and ensure they are documented with current status and next action.
- Check log completeness for the full shift (no missing required fields; notes attached where needed).
- Write handover notes that are actionable: what happened, what’s pending, what the next shift must do first.
- Reset the post (clean, restock to minimum levels, charge devices, return cones/signage to standard layout if required).
Printable-style checklist: End-of-shift reconciliation
END-OF-SHIFT RECONCILIATION Date: ____ Shift: ____ Officer: ____ Post: ____
A) Badge / Pass Control
[ ] Starting stock: ____ Issued: ____ Returned: ____ Ending stock: ____
[ ] Missing/unreturned items listed and escalated (if any)
B) Key / Device Control (if applicable)
[ ] Keys present and secured
[ ] Key log matches physical count
[ ] Any overdue keys/devices escalated
C) Logs & Records
[ ] All required entries completed
[ ] Exceptions have notes/approvals referenced
[ ] Attachments/photos uploaded where required
D) Unresolved Issues / Incidents
[ ] Open items summarized with status and next step
[ ] Maintenance tickets created (if needed): Ticket # ______
[ ] Supervisor notified of critical items
E) Post Readiness
[ ] Radios/devices placed on charge
[ ] Supplies restocked to minimum thresholds
[ ] Area reset to standard configuration
Handover notes (must include: pending actions, broken equipment, expected peaks):
______________________________________________________________________Handover notes: a simple format that prevents missed actions
Use a consistent structure so the next officer can scan quickly.
- Top 3 priorities next shift: e.g., “Replace scanner #2; monitor gate sensor fault; expect delivery surge at 07:30.”
- Open issues with owner and status: “Maintenance ticket 10482—awaiting technician.”
- Temporary controls in place: “Manual verification procedure active until scanner replaced.”
- Anything unusual: “Construction rerouted vehicle lane; cones moved to Plan B.”
4) Performance indicators: measure what “good” looks like
Performance indicators help supervisors and officers see whether the post is stable or drifting. They should be simple enough to track daily and specific enough to trigger action.
Core indicators to track
- Wait times: average and peak wait during known rush windows. Track in minutes and note the lane plan used.
- Incident frequency: count of access-control-relevant incidents per shift (e.g., barrier faults, attempted bypasses, repeated credential failures). Use consistent categories.
- Documentation accuracy: spot-audit error rate (missing required fields, incorrect timestamps, missing approvals). Express as “errors per 10 records” or a percentage.
Practical measurement examples
| Indicator | How to measure quickly | Example target | Trigger for action |
|---|---|---|---|
| Wait time | Record queue start time and time served for 5 samples during peak | < 5 minutes average | Two consecutive peaks > 8 minutes |
| Incident frequency | Tally incidents by category at end of shift | Stable or decreasing trend | Same category repeats 3+ times/week |
| Documentation accuracy | Audit last 10 entries mid-shift | ≥ 95% complete | Any missing critical field; trend < 90% |
Mini scorecard (printable)
DAILY POST SCORECARD Date: ____ Post: ____
Wait time (avg/peak): ____ / ____ minutes Peak window: ____
Incidents (count): ____ Top category: ______________________
Documentation audit: ____ correct out of 10 Notes: __________
What changed today (lane plan, equipment, staffing)? __________
What needs follow-up? ______________________________________5) Improvement cycle: fix the system, not just today’s problem
Continuous improvement in access control means converting repeated friction into updated procedures, better tools, or brief retraining. The cycle should be lightweight: identify, correct, verify, and standardize.
Improvement cycle (step-by-step)
- Report issues consistently: capture what happened, when, and impact (wait time, safety risk, documentation gaps).
- Classify the issue: equipment, staffing/coverage, layout/signage, procedure clarity, or external dependency (maintenance, IT, tenant operations).
- Apply a corrective action: immediate containment plus a longer-term fix.
- Update SOPs/post orders when patterns emerge: if the same workaround appears repeatedly, it should either become an approved temporary control with clear limits or be eliminated by fixing the root cause.
- Brief retraining: short, targeted refreshers (5–10 minutes) tied to a specific observed pattern (e.g., repeated missing fields in logs, inconsistent barrier checks).
- Verify effectiveness: re-check the indicator that should improve (wait time, incident count, audit accuracy) over the next few shifts.
When to update SOPs vs. retrain
- Update SOP/post orders when: the environment changed (new lane layout), tools changed (new scanner model), or the same decision point causes confusion across multiple officers.
- Retrain when: the SOP is clear but not being followed (missed checks, incomplete reconciliation, inconsistent queue adjustments).
- Escalate for engineering/maintenance when: the issue is recurring equipment failure, unsafe barrier behavior, or a layout that repeatedly creates traffic hazards.
Simple corrective-action template (printable)
CORRECTIVE ACTION RECORD (CAR)
1) Issue title: _______________________________________________
2) Date/time observed: __________ Post/location: ______________
3) Reported by: __________________ Supervisor: ________________
4) What happened? (facts only)
________________________________________________________________
5) Impact (check all that apply)
[ ] Safety risk [ ] Security risk [ ] Delay/wait time [ ] Documentation error
Details: _______________________________________________________
6) Immediate containment (what we did right now)
Action: __________________________ By: ________ Time: ________
7) Likely cause (choose one primary)
[ ] Equipment failure [ ] Supply shortage [ ] Procedure unclear
[ ] Staffing/coverage [ ] Layout/signage [ ] External dependency
Notes: _________________________________________________________
8) Corrective action (fix to prevent recurrence)
Action: __________________________ Owner: ______ Due: ________
9) SOP/Post order update needed?
[ ] No [ ] Yes (section/page): __________ Draft by: ___________
10) Brief retraining needed?
[ ] No [ ] Yes (topic): __________________ Date: _____________
11) Verification (how we will confirm it worked)
Metric: __________________________ Target: ____________________
Review date: __________ Result: _______________________________Example: turning a recurring problem into a standard improvement
Pattern: Mid-morning queues spike and officers start skipping the mid-shift spot audit.
- Containment: During peak, assign one officer to queue direction for 15 minutes while the primary officer continues verification steps.
- Corrective action: Update post orders with a peak lane plan and a scheduled audit time immediately after the peak window.
- Retraining: 10-minute refresher on “audit after peak” and how to document lane plan changes.
- Verification: Track peak wait time and audit completion rate for the next 10 shifts.