Residential Wiring Fundamentals: Electrical Terms, Diagrams, and Circuit Thinking

Capítulo 2

Estimated reading time: 10 minutes

+ Exercise

1) Key electrical terms you must use correctly

Voltage (V)

Voltage is electrical “pressure” that pushes charge through a circuit. In residential wiring, you’ll most often work with about 120 V (hot-to-neutral) and 240 V (hot-to-hot) in a typical North American split-phase system.

Current (A)

Current is the flow rate of electricity, measured in amperes (amps). Circuit breakers are sized in amps (e.g., 15 A, 20 A) and are intended to protect the wiring from overheating due to excessive current.

Resistance (Ω)

Resistance is opposition to current flow. Loads (like heaters and lamps) have effective resistance/impedance that determines how much current they draw at a given voltage.

Power (W)

Power is the rate of energy use. In many residential calculations you’ll use:

P = V × I

Example: A 120 V device drawing 5 A uses about 600 W.

Continue in our app.

You can listen to the audiobook with the screen off, receive a free certificate for this course, and also have access to 5,000 other free online courses.

Or continue reading below...
Download App

Download the app

Load

A load is anything that consumes electrical power: lights, receptacles feeding appliances, fans, disposals, etc. In diagrams, loads are the “end devices” connected to the circuit conductors.

Source

The source is where the circuit’s voltage comes from. In a home, the service equipment/panel provides the branch-circuit source through a breaker, then the circuit conductors distribute it to loads.

Hot (ungrounded conductor)

The hot conductor is the energized conductor that provides voltage relative to neutral/ground. In typical cables it’s black or red (colors can vary). A switch usually interrupts the hot, not the neutral.

Neutral (grounded conductor)

The neutral is the intended return path for current on 120 V circuits. It is connected to the system’s grounded point at the service equipment (main panel) and is typically white or gray. Neutrals must be continuous and properly spliced because an open neutral can cause loads to behave unpredictably and create abnormal voltages in multi-wire arrangements.

Equipment grounding conductor (EGC)

The equipment grounding conductor is the safety grounding path for metal parts of equipment and boxes. It normally carries no current, but it provides a low-impedance path during a fault so protective devices can operate. It is typically bare copper or green insulated.

Grounding vs bonding

  • Grounding means connecting a system to earth (via grounding electrode system) to stabilize voltage to earth and manage surges.
  • Bonding means connecting metal parts together (and to the equipment grounding system) so they are at the same electrical potential and so fault current has a reliable path back to the source.

Practical distinction: bonding is about metal continuity and fault clearing; grounding is about reference to earth and surge/voltage stabilization.

2) AC basics for homes (without deep theory)

What “AC” means in practice

Alternating current changes direction many times per second. For wiring layout and circuit thinking, the key point is that current must have a complete path from the source, through the load, and back to the source—regardless of direction changes.

120/240 V split-phase concept

Most North American homes use a split-phase system. The transformer provides two hot legs and a neutral:

  • Hot L1 to Neutral ≈ 120 V
  • Hot L2 to Neutral ≈ 120 V
  • Hot L1 to Hot L2 ≈ 240 V

How this shows up in wiring:

  • 120 V circuits use one hot + neutral (+ equipment ground).
  • 240 V circuits typically use two hots (+ equipment ground). Some 240 V loads also need a neutral (e.g., certain ranges/dryers) for 120 V components.

Panel thinking: a 120 V breaker connects to one hot leg; a 2-pole breaker connects to both legs to supply 240 V.

3) Symbols and diagram types you’ll read and sketch

Three common diagram “views”

Diagram typeWhat it showsBest for
Floor-plan wiring layoutDevice locations in rooms and approximate cable routesPlanning rough-in, box placement, cable routing
Single-line (one-line) diagramSimplified connections from panel to loads (not every conductor drawn)Understanding circuit grouping, panel schedules, feeders/branch circuits
Simple schematicFunctional connections (how switches control loads)Understanding switching, travelers, splices, and circuit logic

Common residential symbols (conceptual)

Symbols vary by print set, but these are widely recognized ideas:

  • Receptacle: duplex outlet symbol (often a small circle or “receptacle” mark on plan).
  • Switch: “S” or specific switch symbol near the door; lines may show which light it controls.
  • Ceiling light / luminaire: circle with marking; sometimes “L” or a fixture symbol.
  • Junction box (J-box): a box where splices occur; may be shown as a square/rectangle/circle depending on plan style.
  • Panelboard: labeled rectangle (e.g., “Panel”) with circuits listed in a schedule.

How to read a floor-plan wiring layout

Focus on three questions:

  • Where are the devices? (switches, lights, receptacles, dedicated outlets)
  • How are they grouped into circuits? (often indicated by circuit numbers or homerun tags)
  • Where do cables likely run? (up walls, through framing, to attic/basement routes, then to next device)

A “home run” is the cable run from the first box in a circuit back to the panel (or sometimes from a key junction box back to the panel). On drawings it may be marked with a circuit number.

How to read a single-line diagram

A single-line diagram intentionally does not show every conductor. It shows “Circuit A feeds these loads” and may show breaker size. Think of it as a map of what is connected, not how the cable is physically routed.

Simple schematics for switches and receptacles

Use schematics to verify the current path and where splices must occur. Here are two foundational schematics you should be able to sketch.

(A) Switch controls a ceiling light (power to switch box)

Panel hot ──────> Switch ──────> Light hot (switched hot) ──┐  (through lamp)  ┌── Light neutral ──────> Panel neutral

Key idea: the switch interrupts the hot. Neutral bypasses the switch and goes to the light.

(B) Receptacle on a 120 V branch circuit (daisy-chained)

Panel hot ──> Receptacle 1 hot terminal ──> onward hot ──> Receptacle 2 hot terminal ...
Panel neutral ──> Receptacle 1 neutral terminal ──> onward neutral ──> Receptacle 2 neutral terminal ...
Panel ground ──> bond box/device ──> onward ground ...

Key idea: hot, neutral, and ground all continue through the run; splices/pigtails may be used so device removal doesn’t break continuity.

4) Circuit paths and return paths (why neutrals matter)

What a “complete circuit” means

A load operates only when there is a continuous path from the source, through the load, and back to the source. For a typical 120 V lighting circuit:

  • Path out: breaker → hot conductor → switch (if on) → light
  • Return path: light → neutral conductor → neutral bar (service grounded point) → transformer

The equipment grounding conductor is not intended to be the normal return path.

Why neutral integrity is critical

Neutral problems can be confusing because the hot may still be present at a device, but the circuit won’t work correctly if the neutral is open or has a poor connection. Practical outcomes of a compromised neutral can include:

  • Lights that don’t turn on even though the switch has power
  • Intermittent operation when a splice is loose
  • Unexpected voltage readings due to backfeed through connected loads

In circuit sketches, always draw the neutral path as deliberately as the hot path. If you can’t trace the neutral from each load back to the source, the sketch is incomplete.

How faults occur (circuit-thinking view)

A fault is an unintended connection or unintended path. Common fault categories from a diagram perspective:

  • Hot-to-ground fault: hot contacts metal box/device yoke; fault current returns via bonding/EGC path toward the source.
  • Hot-to-neutral fault (short): hot contacts neutral; very high current can flow.
  • Open circuit: a break in hot or neutral (open hot = nothing works downstream; open neutral = unpredictable behavior).

When you sketch, mark where a fault would “return” to the source. If you can’t see a low-impedance return path for a ground fault, your bonding/grounding depiction is incomplete.

5) Practice: convert a room layout into a circuit sketch

Scenario (room layout description)

You are wiring a simple bedroom. Devices:

  • One ceiling light (center of room)
  • One switch by the door controlling the ceiling light
  • Four general-purpose receptacles around the room
  • One smoke alarm on the ceiling (assume it’s on a lighting circuit for this exercise)
  • Panel is in the basement below the room (choose a “home run” path down an interior wall)

Step 1: Draw a simple floor-plan wiring layout (device placement)

On a blank rectangle (the room):

  • Place the door on one wall; place the switch next to it.
  • Place the ceiling light at the center.
  • Place receptacles spaced around the perimeter (R1–R4).
  • Place the smoke alarm on the ceiling (SA1), near the hallway side if desired.

Label each device with a short ID (S1, L1, R1–R4, SA1). Good sketches are readable before they are “perfect.”

Step 2: Decide circuit grouping and breaker identification

For practice, use two 120 V circuits:

  • Circuit 1 (Lighting): S1, L1, SA1 on a 15 A breaker (example)
  • Circuit 2 (Receptacles): R1–R4 on a 20 A breaker (example)

On your sketch, write “Ckt 1” next to S1/L1/SA1 and “Ckt 2” next to R1–R4. This is the first step toward a one-line diagram mindset.

Step 3: Choose cable routes and junction points (think like the wire)

Pick a logical routing method. Two common approaches:

  • Daisy-chain: panel → first device → next device → next device
  • Junction-centered: panel → junction box → branches to multiple devices

For this room, use daisy-chaining for receptacles and a junction at the ceiling box for lighting/smoke alarm.

Example routing choices:

  • Ckt 1: Panel → S1 → L1 (ceiling box) → SA1
  • Ckt 2: Panel → R1 → R2 → R3 → R4

On the floor plan, draw light lines showing the approximate cable path (up from panel to S1/R1, then across framing to other points). Mark any point where you expect splices (ceiling box often acts as a junction for lighting).

Step 4: Convert the floor plan into a single-line diagram

Now redraw as a simplified connectivity map (not physical routing). Example:

Panel (Ckt 1) ──> S1 ──> L1 ──> SA1
Panel (Ckt 2) ──> R1 ──> R2 ──> R3 ──> R4

Add breaker labels such as “Bkr 1: 15 A” and “Bkr 2: 20 A” if desired. The goal is to clearly show what is fed by what.

Step 5: Add a simple schematic layer (hot, neutral, ground paths)

Pick one circuit at a time and sketch conductor intent. For Circuit 1 (lighting):

  • Hot leaves breaker and goes to S1 common.
  • Switched hot leaves S1 and goes to L1 hot.
  • Neutral from panel goes to L1 neutral (and continues to SA1 neutral if SA1 is on this circuit).
  • Equipment ground bonds all metal boxes/devices and continues through.

Represent it with a compact sketch:

Ckt 1 HOT:   Panel ──> S1 ──(switched hot)──> L1 ──> SA1 (if fed onward by hot feed as required)
Ckt 1 NEU:   Panel ────────────────> L1 ────────────────> SA1
Ckt 1 EGC:   Panel ────────────────> bond all boxes/devices ────────────────> onward

For Circuit 2 (receptacles):

Ckt 2 HOT:   Panel ──> R1 ──> R2 ──> R3 ──> R4
Ckt 2 NEU:   Panel ──> R1 ──> R2 ──> R3 ──> R4
Ckt 2 EGC:   Panel ──> bond ──> bond ──> bond ──> bond

Step 6: Mark junction boxes, splices, and “home run” points

On the floor plan, mark:

  • Home run (HR) for Ckt 1: from panel to S1 (HR1) and for Ckt 2: from panel to R1 (HR2).
  • Ceiling box as junction: at L1, note that neutrals are spliced through (panel neutral to lamp neutral and onward to SA1 neutral if applicable).
  • Device feed-through points: at R1–R3, note that hot/neutral/ground continue onward to the next receptacle.

This step forces you to think about where conductors must be continuous and where a single loose connection would affect downstream devices.

Step 7: Self-check questions (use your sketch to answer)

  • If S1 is off, does any current flow through L1? (Your schematic should show the hot path is open.)
  • If the neutral splice at L1 is open, what stops working? (L1 and anything downstream on that neutral path.)
  • Where is the return path for normal current on Circuit 2? (Neutral back to panel/transformer.)
  • Where is the intended return path during a hot-to-metal fault at R3? (Bonded metal/EGC path back toward the source.)

Now answer the exercise about the content:

In a typical 120 V lighting circuit where a switch controls a ceiling light, which statement best describes the intended current paths when the light is on?

You are right! Congratulations, now go to the next page

You missed! Try again.

In normal operation, the hot feeds the switch and load, and the neutral provides the intended return path back to the source. The equipment grounding conductor is a safety path for fault clearing, not the normal return.