Three Common Categories for Residential Backup
Home backup generators generally fall into three practical categories: portable inverter generators, open-frame portable generators, and whole-home standby generators. Choosing between them is less about “best” and more about matching your load plan, expected outage duration, noise constraints, and how you will connect power safely to the home.
| Category | Typical continuous output | Best fit | Main tradeoffs |
|---|---|---|---|
| Portable inverter | 1,000–4,000 W (some parallel to 6,000–8,000 W) | Electronics-friendly, quiet neighborhoods, short-to-medium outages | Higher cost per watt; limited 240 V options at smaller sizes |
| Open-frame portable | 3,000–9,500 W | Higher wattage on a budget; larger motor loads | Louder; higher THD on many models; weather protection needed |
| Standby (fixed) | 10–26 kW (common residential range) | Automatic whole-home or large partial-home backup | Highest installed cost; requires permanent fuel supply and routine service |
Portable Inverter Generators
What they are and why homeowners choose them
An inverter generator produces AC power by first generating DC and then “inverting” it to a controlled sine wave. This design typically enables lower total harmonic distortion (THD), steadier frequency control, and variable engine speed (the engine can slow down under light loads), which reduces fuel use and noise.
Power quality: THD, electronics, and sensitive loads
Many inverter generators advertise low THD (often < 3% THD for the inverter output). Lower THD generally means less electrical “noise,” which is friendlier to devices with switching power supplies and microelectronics (computers, routers, modern TVs, battery chargers). Practical guidance:
- If you expect to run sensitive electronics for long periods, prioritize an inverter model that specifies THD and has a reputation for stable voltage regulation.
- Even with low THD, avoid operating near maximum continuous output for long stretches; headroom improves voltage stability and reduces nuisance shutdowns.
Noise ratings and neighborhood practicality
Inverter units are often rated around 50–60 dBA at a specified distance (commonly 7 m / 23 ft, but check the fine print). Because they can idle down, they may be notably quieter at partial load than open-frame units. When comparing noise specs, ensure you compare the same distance and load condition.
Portability and weather protection
Most inverter generators are enclosed “suitcase” or enclosed-frame designs, which helps with noise and offers some splash resistance, but they are not weatherproof. Plan for a dry, well-ventilated operating location and a purpose-built generator tent/canopy if needed (never enclose in a way that traps exhaust).
Continue in our app.
You can listen to the audiobook with the screen off, receive a free certificate for this course, and also have access to 5,000 other free online courses.
Or continue reading below...Download the app
Starting methods
- Recoil start: simplest, fewer parts; can be harder in cold weather or for some users.
- Electric start: push-button convenience; requires battery maintenance and periodic charging.
- Remote start (some models): convenience feature; still requires safe placement and setup before use.
Maintenance expectations
Inverter generators still have small engines that need routine care: oil changes, air filter service, spark plug checks, and fuel management. Because many are used intermittently, fuel storage discipline (fresh fuel, stabilizer if appropriate, draining carburetor for long storage) is often the difference between “starts every time” and “won’t start when needed.”
Open-Frame Portable Generators
What they are and why homeowners choose them
Open-frame portables are the classic construction-style generators: an engine directly drives an alternator at a fixed speed to produce AC power. They are popular because they deliver more watts per dollar and often provide 240 V output at higher wattages, which can be useful for certain home loads.
Power quality considerations (THD and voltage regulation)
Power quality varies widely by model. Many conventional open-frame units can have higher THD and less precise voltage regulation than inverter units, especially under changing loads. Practical guidance:
- If you plan to power sensitive electronics, look for models that specify low THD or include “clean power” features; otherwise consider keeping electronics on a UPS or using an inverter generator for those circuits.
- Motor loads (like some pumps or furnace blowers) often tolerate conventional generator output well, but starting surges must be accounted for.
Noise and placement
Open-frame units are typically louder (often 65–80+ dBA depending on size and load). That affects where you can place them and how acceptable they are during overnight outages. Distance, barriers, and orientation matter, but never compromise ventilation or safe exhaust routing.
Portability and weather protection
These units are heavier and bulkier, but many include wheel kits. They are generally more exposed to rain and snow. Plan for:
- A stable, level surface.
- Protection from precipitation that does not restrict airflow.
- Extra attention to cord routing and keeping connections dry.
Starting methods
Open-frame units commonly offer recoil start; mid-to-large models often add electric start. Electric start is especially helpful on larger engines where pull-start force is significant.
Maintenance expectations
Maintenance is similar to inverter units but often with larger oil capacity and longer run times. Because these are frequently stored in garages or sheds, periodic test runs and fuel system care are important.
Whole-Home Standby Generators
What they are and why homeowners choose them
A standby generator is a permanently installed unit connected to a home’s electrical system through an automatic transfer mechanism and supplied by a permanent fuel source (commonly natural gas or a dedicated propane tank). The key homeowner benefit is automatic operation: when utility power fails, the system starts and transfers power without manual setup.
Power quality and suitability for electronics
Many modern standby generators provide good voltage regulation and stable frequency, suitable for typical household electronics. However, “power quality” still varies by brand and model. If you have especially sensitive equipment, review published specifications (voltage regulation, frequency stability, THD if provided) and consider whole-house surge protection as part of the system design.
Noise ratings and community constraints
Standby units are often quieter than open-frame portables and comparable to or slightly louder than large inverter portables, depending on size and enclosure. They are typically rated at a standardized distance and may have “quiet test” modes for weekly exercise cycles. Local ordinances and HOA rules may influence placement and acceptable sound levels.
Weather protection and durability
Standby generators are designed for outdoor installation with weather-resistant enclosures. Even so, placement matters: avoid areas prone to drifting snow, flooding, or roof runoff, and maintain clearances for airflow and service access.
Maintenance expectations
Standby systems require scheduled service similar to a small engine plus additional checks (battery condition, exercise cycle verification, inspection of fuel supply components). Many owners choose an annual service plan. Expect periodic battery replacement and oil/filter changes based on run hours and calendar time.
Understanding Continuous vs Surge Ratings (Why the Label Matters)
Generator nameplates usually list at least two power numbers:
- Continuous (running/rated) watts: what the generator can supply continuously without overheating or overloading.
- Surge (starting/peak) watts: extra power available briefly to start motors or handle short inrush events.
Why it matters in practice:
- Many household loads have inrush current (refrigerator compressor, well pump, sump pump). If surge capacity is too low, the generator may stall, trip a breaker, or cause voltage sag that resets electronics.
- Running near the continuous rating for long periods increases heat and can shorten engine life. A common planning approach is to keep typical running load at or below about 70–80% of continuous rating for better stability and longevity.
Example (simplified):
- Generator: 4,000 W continuous / 5,000 W surge
- Loads running: 2,800 W total
- Refrigerator start surge: +1,200 W momentary
Result: 2,800 + 1,200 = 4,000 W momentary (OK if surge is adequate and duration is short)Typical Output Ranges and What They Enable (Decision-Oriented)
Portable inverter: 1–4 kW (single unit) or higher with parallel kits
- Commonly supports essentials and electronics with low noise.
- Parallel capability can be a strategy: one unit for short outages, two units for longer outages or higher loads.
Open-frame portable: 5–9.5 kW
- Often chosen when you need more wattage and 240 V capability in a portable format.
- Better suited for larger motor loads, but confirm surge capacity and consider power quality needs.
Standby: 10–26 kW
- Supports larger portions of the home with automatic operation.
- Often paired with load management or a prioritized panel so the generator isn’t forced to carry every load at once.
Step-by-Step: Selection Checklist (Tie Generator Type to Your Plan)
Step 1: Classify your loads by sensitivity and starting behavior
- Sensitive electronics: prioritize low THD and stable voltage (often favors inverter or well-specified standby).
- Motor/compressor loads: prioritize surge capacity and 240 V availability if required.
- Mixed loads: consider separating sensitive electronics onto a UPS or choosing a generator with better power quality.
Step 2: Decide your runtime strategy (hours to days)
- Short outages: portability and quick setup may matter more than automation.
- Multi-day outages: fuel logistics, refueling frequency, and maintenance intervals become central; standby units reduce manual effort, while portables require disciplined refueling and monitoring.
Step 3: Match the generator category to your constraints
- Need quiet + electronics-friendly power: portable inverter (or a standby model with strong regulation specs).
- Need maximum watts per dollar: open-frame portable, with careful attention to THD and surge ratings.
- Need automatic, hands-off operation: standby generator.
Step 4: Verify continuous and surge ratings against your expected operating pattern
- Ensure the continuous rating covers your typical simultaneous loads with headroom.
- Ensure the surge rating covers the largest starting event you expect (or plan to stagger starts).
Step 5: Check starting method and who will operate it
- If multiple household members may need to start it, electric start can reduce failure-to-start risk.
- For standby systems, verify battery maintenance expectations and exercise cycle settings.
Step 6: Plan for weather exposure and storage
- Portables: confirm you have a safe, ventilated location protected from precipitation and a storage plan that keeps the unit ready.
- Standby: confirm placement clearances, service access, and that the installation location avoids common water and snow issues.
Step 7: Confirm safe connection method to the home before buying
Your generator choice should align with how it will be interconnected:
- Portable generators are commonly used with a dedicated inlet and transfer equipment sized for the generator’s output (including 120/240 V considerations and connector type). Confirm the generator has the receptacle configuration you need (for example, 120/240 V locking outlet on larger units).
- Standby generators are designed to integrate with an automatic transfer setup and are typically sized and configured as part of the installation plan.
Before purchase, verify the generator’s output voltage options, receptacle types, and maximum current align with the intended safe interconnection hardware so you are not forced into unsafe or improvised connections during an outage.