Operating mindset: repeatable sequences and “no surprises”
During an outage, most generator problems come from skipped steps: starting under load, transferring too quickly, or overloading with multiple large appliances at once. The goal of an operating procedure is to make each run predictable: verify the generator is ready, start it with no load, transfer correctly, add loads in stages, monitor performance, then shut down and return to utility power in a controlled way.
Use the checklists below as written procedures you can print and keep with the generator, transfer equipment, and fuel/oil supplies.
Pre-start checklist (applies to all generator types)
1) Site, placement, and ventilation
- Outdoor only for portable units: place on a stable, level surface where exhaust cannot enter doors, windows, soffit vents, crawlspace vents, or garage openings.
- Clearance: keep the exhaust side unobstructed; remove snow, leaves, or debris that could block airflow.
- Weather protection: keep the generator dry without enclosing it in a way that traps exhaust or heat. (Use a purpose-built canopy if available.)
- Fire safety: keep fuel containers away from hot mufflers and away from ignition sources.
2) Fuel and oil
- Fuel level: confirm enough fuel for the planned run window (e.g., overnight vs short daytime runs).
- Oil level: check dipstick; top off with the correct grade if needed.
- Leaks: look and smell for fuel or oil leaks before starting.
- Propane/natural gas standby: verify gas supply valve position and that there are no obvious damage/odor issues; if you smell gas, stop and follow your gas utility’s emergency guidance.
3) Electrical condition (cords, inlet, and generator receptacles)
- Generator cord/inlet cord: inspect for cuts, crushed sections, melted insulation, loose plugs, or bent blades.
- Connections: confirm plugs seat fully and locking connectors twist/lock completely.
- Dryness: ensure connectors are dry and off the ground where possible.
- Generator breakers: set generator output breakers to OFF before starting (portable units).
4) Generator controls (portable)
- Fuel valve: ON (if equipped).
- Choke: set for cold start (if equipped).
- Eco/idle control: many manufacturers recommend OFF for starting and initial warm-up; follow your unit’s label/manual.
5) House readiness
- Know your “first loads”: pick a short list of essential circuits/appliances to energize first (lights, fridge, furnace blower, etc.).
- Turn off big loads at the appliance or breaker if you don’t want them to start immediately (electric range, dryer, large HVAC, etc.).
Manual transfer switch / interlock operating sequence
This sequence assumes you have a code-compliant manual transfer method already installed (manual transfer switch or panel interlock with generator inlet). The key idea is: start with the generator unloaded, then transfer, then add loads gradually.
A. Startup and connection (portable generator feeding an inlet)
- Confirm transfer equipment is in the utility position (or generator position is OFF) before doing anything else.
- At the generator: ensure output breakers are OFF.
- Connect the generator cord to the generator receptacle and to the inlet box (lock both ends if twist-lock).
- Start the generator (choke as needed). Let it stabilize.
- Warm-up: run 1–3 minutes with no load (longer in very cold weather).
- Turn generator output breaker(s) ON.
B. Transfer steps (manual transfer switch)
- Isolate utility: move the transfer switch from UTILITY to GENERATOR (or switch individual circuits to GENERATOR as your device requires).
- Energize loads in stages: switch on essential circuits one at a time, waiting 10–30 seconds between larger loads.
- Listen and observe: if the engine bogs, lights dim heavily, or the generator sounds strained, back off by turning off the last load added.
C. Transfer steps (panel interlock)
- At the main panel: turn OFF selected branch breakers you don’t want initially (optional but recommended for a smooth transfer).
- Isolate utility: turn the main breaker OFF.
- Engage the interlock per its mechanism so the generator backfeed breaker can be turned ON while the main is OFF.
- Turn ON the generator breaker in the panel.
- Energize branch circuits in stages: turn on priority breakers one by one. Start with small/steady loads, then add motor loads (fridge, well pump) one at a time.
Practical staging example (manual systems)
| Stage | What to turn on | Why |
|---|---|---|
| 1 | Basic lighting circuits, internet/router | Low surge, confirms stable power |
| 2 | Refrigerator/freezer (one at a time) | Motor surge; avoid simultaneous starts |
| 3 | Furnace/boiler blower or small space heater (if planned) | Moderate load; verify generator holds speed |
| 4 | Well pump / sump pump (one at a time) | High surge; test after essentials are stable |
Automatic standby system operating sequence (ATS)
With an automatic standby generator and automatic transfer switch (ATS), the system detects utility loss, starts the generator, and transfers automatically. Your job is to monitor, avoid adding unnecessary loads, and know how to place the system in a safe mode if something abnormal happens.
A. Normal automatic operation (typical sequence)
- Utility fails → controller senses outage.
- Generator starts and reaches stable speed/voltage.
- ATS transfers the house load to generator.
- Load management features (if equipped) may shed or delay certain loads automatically.
B. Homeowner checklist during an automatic event
- Wait before adding extra loads: let the system settle for a few minutes.
- Check the controller display/indicators: look for warnings (low battery, overspeed, low oil pressure, overload).
- Listen for strain: persistent hunting (revving up/down), heavy bogging, or repeated transfer attempts indicate a problem.
- Keep doors/windows closed near the unit to reduce the chance of exhaust entering the home.
C. If you need to stop automatic operation
Use the generator controller’s mode switch (often AUTO/OFF/MANUAL). If there is an unsafe condition (smoke, fuel leak, abnormal noise), set to OFF and keep clear. If you are unsure, contact your service provider.
Continue in our app.
You can listen to the audiobook with the screen off, receive a free certificate for this course, and also have access to 5,000 other free online courses.
Or continue reading below...Download the app
Load management during generator operation
Core rules
- Avoid overload: if the generator is near its limit, voltage can sag and frequency can drift, causing motors and electronics to run hot or malfunction.
- One big motor at a time: refrigerator, freezer, well pump, sump pump, and some furnace blowers have starting surges. Don’t let them all start simultaneously.
- Rotate high-demand loads: run one major load for a period, then switch it off and run another (e.g., microwave briefly, then back to fridge and lights).
- Prioritize “must-run” loads: medical devices, refrigeration, heating controls, and essential lighting first.
Using indicators (if available)
- Generator watt/amp meter: stay below the continuous rating; treat frequent peaks as a sign to reduce loads.
- Voltage: significant drop under load suggests overload or a connection issue. Reduce load first.
- Frequency (Hz): low frequency often indicates the engine is lugging. Reduce load and let it recover.
Simple rotation plan example
00:00–00:10 Run well pump (if needed) + lights only (avoid fridge starting at same time) 00:10–01:00 Run fridge/freezer cycling + furnace blower as needed 01:00–01:05 Microwave/coffee maker (temporarily turn off other heavy loads) 01:05–02:00 Back to essentials; charge phones/laptops 02:00–02:10 Sump pump test/run window (if conditions require)Adjust the schedule to your home’s needs; the point is to prevent multiple high-demand loads from stacking.
Shutdown and retransfer procedures
A. Manual transfer switch / interlock: returning to utility
- Prepare the house: turn OFF or unplug sensitive/high loads (space heaters, microwave, window AC, etc.).
- Remove load from the generator: switch branch circuits OFF in stages (or move transfer circuits back to OFF/UTILITY-ready positions).
- Retransfer to utility:
- Manual transfer switch: move from GENERATOR to UTILITY.
- Interlock: turn OFF the generator breaker, slide interlock, then turn ON the main breaker.
- Cool-down: let the generator run with no load for 2–5 minutes (longer after heavy loading) to stabilize temperatures.
- Stop the generator: switch OFF/stop per manufacturer procedure; close fuel valve if equipped.
- Disconnect and store: unplug cord ends, cap/cover inlet if applicable, coil cord without tight kinks, store dry.
B. Automatic standby: utility return
Most systems automatically retransfer back to utility after it is stable for a set time, then run a cool-down cycle and stop. Your checklist:
- Confirm retransfer happened (controller/ATS indicator shows utility supply).
- Let the cool-down complete; avoid switching the controller OFF mid-cycle unless there is a safety concern.
- After the event, check for any alerts and note run hours if your maintenance plan tracks them.
Post-run inspection (5-minute routine)
- Fuel: note remaining fuel; refuel only when the unit is off and cooled.
- Oil: check level after cooldown; top off if needed (follow manufacturer guidance on when to check).
- Cords and plugs: feel for unusual warmth at connectors (warm is a warning sign); inspect for discoloration or melting.
- Generator exterior: look for soot changes, loose fasteners, or vibration-related movement.
- Area check: ensure the generator location is left safe—no spilled fuel, no hot surfaces near combustibles.
Troubleshooting flow (keep safety first)
If something goes wrong, the safest first move is usually: reduce load and stop transferring/connecting until the generator is stable. Use this flow to decide what to do next.
1) Overload trip (generator breaker trips or engine bogs hard)
- Immediate action: turn OFF or disconnect loads (start with the last load added). If using an interlock/manual transfer switch, turn off several branch breakers quickly.
- Reset: once load is reduced, reset the generator breaker (or panel generator breaker if it tripped).
- Re-add loads slowly: one circuit at a time, with pauses.
- If it trips again: you are still overloaded or a specific circuit/appliance is drawing too much. Leave that circuit OFF and continue with essentials only.
2) Low power symptoms (dim lights, slow appliances, low voltage/frequency reading)
- Reduce load immediately (turn off heaters, microwave, pumps, or other heavy loads).
- Check eco/idle mode: some portables respond poorly to sudden loads in eco mode; follow your unit’s recommended setting.
- Check cord/inlet connections: with power removed (generator breaker OFF), inspect for loose plugs or overheated connectors.
- If still low: stop and investigate fuel quality/level, air filter blockage, or service issues. Do not continue powering sensitive electronics if voltage/frequency is unstable.
3) Stalling or repeated shutdown
- Unload first: transfer back to utility if available, or turn off branch circuits/transfer switch circuits to remove load.
- Fuel check: confirm fuel valve ON, adequate fuel, and no obvious contamination (water/debris) if applicable.
- Oil and alerts: many units shut down on low oil; check oil level and any indicator lights.
- Restart unloaded: start with generator breakers OFF, warm up, then reapply loads gradually.
- If it continues: treat as a mechanical/service issue; keep loads off and seek service.
4) Flickering lights (intermittent, rhythmic, or when loads start)
- Identify pattern: flicker only when a motor starts suggests surge stacking; flicker continuously suggests unstable speed/voltage or a poor connection.
- Reduce simultaneous starts: temporarily turn off one motor load (e.g., freezer) while another runs (e.g., well pump).
- Check connections for heat: after removing load and turning breakers OFF, inspect plugs/inlet for looseness or discoloration.
- If flicker persists with minimal load: stop using the generator for sensitive electronics and troubleshoot the generator output stability or connection hardware.
5) “No power to house” after starting generator (manual systems)
- Verify transfer position: confirm the transfer switch is actually in GENERATOR position, or the interlock sequence is correct (main OFF, generator breaker ON).
- Verify generator output breaker: ON at the generator.
- Verify cord seating: fully inserted and locked at both ends.
- Try a known small load: turn on a single lighting circuit to confirm basic transfer before adding more.
Safety stop conditions (stop and keep clear)
- Fuel leak, smoke, or fire risk
- Exhaust entering the home (headache, nausea, CO alarm)
- Overheated/melting connectors or burning smell from cords/inlet/panel
- Generator making loud mechanical knocking or grinding sounds
- Repeated tripping that cannot be resolved by reducing load