Fuses and relays are the “gatekeepers” of many automotive circuits. A fuse is a deliberate weak link that opens when current exceeds a safe limit, protecting wiring and connectors from overheating. A relay is an electrically controlled switch: a small control current energizes a coil, which moves contacts that can carry much higher current to a load (fan, pump, lights, etc.).
Identifying fuse types and ratings (what you’re looking at)
Common automotive fuse styles
- Blade fuses (micro/mini/ATO): plastic body with two blades; often have small exposed metal test points on top.
- Cartridge/J-case fuses: larger, higher-current circuits (cooling fans, ABS, power distribution).
- Fusible links / fuse strips: used near the battery or power distribution; protect large feeds.
Fuse ratings: what the number means
The fuse’s amp rating is chosen to protect the wiring and connectors, not the component. If a circuit is designed for a 15A fuse, installing a 25A fuse can allow the harness to overheat before the fuse opens.
- Match the rating exactly (same amperage and same style).
- Do not “upsize” to stop a fuse from blowing—find the cause (shorted load, chafed wire, wrong bulb, etc.).
- Color is a clue, not a guarantee: many blade fuses use standardized colors, but always confirm the stamped rating.
Common fuse pitfalls
- Assuming “looks good” = good: hairline breaks can be hard to see.
- Wrong fuse location: multiple fuse panels exist (underhood and interior). Verify you’re on the correct circuit.
- Backfeeding confusion: some circuits can show voltage on the load side through another path, even with an open fuse. The “power on both sides under load” check helps avoid this.
Testing fuses in place with voltage checks (fast and reliable)
In-vehicle fuse testing is best done with voltage checks at the fuse’s top test points. This confirms not only that the fuse element is intact, but also that the fuse is being fed with power when it should be.
Step-by-step: voltage check at the fuse test points
- Set the circuit state correctly: key position and switch position must match when the circuit is supposed to be powered (e.g., key ON, headlights ON, blower ON).
- Meter setup: DC volts. Black lead to a known good ground point (battery negative post or a clean chassis ground). Red lead will probe the fuse test points.
- Probe test point A (one side of the fuse): note the voltage.
- Probe test point B (the other side of the fuse): note the voltage.
How to interpret the readings
| Reading at test point A | Reading at test point B | Meaning | Next move |
|---|---|---|---|
| ~12V | ~12V | Fuse is intact and powered | Go downstream (relay/load/ground) |
| ~12V | 0V | Fuse is open (blown) or poor contact at fuse blades | Confirm with voltage drop across fuse; inspect/replace fuse and check terminals |
| 0V | 0V | No feed power to the fuse (upstream issue) | Check upstream fuse, fusible link, power distribution, ignition feed |
| 0V | ~12V | Unusual; often backfeed through the load or another circuit | Turn load on/off and recheck; verify correct fuse and circuit diagram |
Confirming power on both sides (and why it matters)
“Power on both sides” is the quickest confirmation that the fuse is not only unblown but also receiving power. If only one side has voltage, the fuse is not passing current. If neither side has voltage, the fuse may be fine but the circuit isn’t being fed (wrong key position, failed upstream feed, or wrong fuse).
Optional precision check: voltage drop across the fuse
If the circuit is ON and drawing current, you can measure directly across the fuse:
Continue in our app.
You can listen to the audiobook with the screen off, receive a free certificate for this course, and also have access to 5,000 other free online courses.
Or continue reading below...Download the app
- Meter on DC volts
- Red lead on one fuse test point, black lead on the other test point
A good fuse under load should show near 0V drop (typically a few millivolts). A blown fuse will show battery voltage across it. This method also helps reveal poor contact at the fuse blades or corroded terminals (you may see an unexpected voltage drop even if the fuse element is intact).
Relays: how they switch high current with low-current control
A relay separates a low-current control circuit (switch/module output) from a high-current load circuit (motor, heater, lamps). The control side energizes a coil (electromagnet). The coil pulls a movable contact that connects the high-current feed to the load.
Pin identification: coil vs. contacts
Most ISO micro relays use a standardized numbering scheme. Always verify the diagram printed on the relay case or the relay box legend.
Typical 4-pin relay (NO = normally open) Typical 5-pin relay (adds NC contact) Coil side: 85 and 86 Contact side: 30 (common), 87 (NO), 87a (NC on 5-pin) 30 = power in (from fuse) 87 = power out to load when energized 85/86 = coil terminals (one gets power, the other ground; sometimes switched) 87a = power out to load when relay is NOT energized (only on 5-pin)Key idea: The coil circuit and the contact circuit are electrically separate. You can have a relay that “clicks” (coil works) but still doesn’t pass power (burned contacts), or a relay that has good contacts but never energizes (no control power/ground).
Quick activation check: listen and feel
- Place a fingertip on the relay body.
- Command the circuit ON (turn the switch on, request fan, etc.).
- Click felt/heard suggests the coil is energizing and moving the armature.
Pitfall: A click does not guarantee current is reaching the load. Contacts can be pitted, resistive, or the high-current feed may be missing.
Testing the relay control side (coil power and coil ground)
Use the relay socket (back-probe carefully) so you’re testing the circuit, not just the relay.
Step-by-step: verify coil power
- Identify coil pins (usually 85 and 86) from the relay diagram.
- With the circuit commanded ON, measure voltage from the suspected coil power terminal to ground.
- Expected: near battery voltage on the coil power side when the system requests activation.
Step-by-step: verify coil ground (or switched ground)
- Keep the circuit commanded ON.
- Measure voltage at the suspected coil ground terminal to battery negative (or a known good ground).
- Interpretation: if it’s a true ground, it should be near 0V when commanded ON. If the module provides a switched ground, you may see it pull low only when activation is requested.
Alternative method: Measure across the coil terminals (85 to 86). When the relay is commanded ON, you should see near battery voltage across the coil. If you see 0V across the coil while commanded ON, the coil isn’t being driven (missing power, missing ground, or wrong command state).
Testing the relay contact side (power in and power out)
Identify the high-current feed terminal (usually 30) and the output to the load (usually 87).
- Check terminal 30 to ground: should have battery voltage whenever that fuse/feed is present (sometimes constant, sometimes key-switched).
- Command relay ON.
- Check terminal 87 to ground: should rise to near battery voltage when the relay is energized.
Common pitfall: Confusing 87 and 87a on a 5-pin relay. If you probe 87a expecting output when energized, you’ll see the opposite behavior.
Structured troubleshooting scenario: “Component not powered” (fuse feed → relay control → load ground)
This scenario assumes a typical layout: battery power goes through a fuse to relay terminal 30; the relay coil is controlled by a switch/module; the relay sends power from 30 to 87 to the component; the component returns to ground.
Text diagram of the circuit
(Battery +) → [Fuse] → (Relay terminal 30) Relay coil: (85) ← control ground or power from switch/module → (86) When coil energized: 30 connects to 87 (Relay terminal 87) → [Load/Component +] → [Component] → [Ground point] → (Battery -)Goal: find where voltage stops (use the same ground reference)
Use a consistent, known-good ground for your meter’s black lead (battery negative post is ideal for clarity). Command the component ON during these checks.
Step 1 — Verify the fuse is powered and passing power
- Locate the fuse that feeds the relay contact side (often labeled for the component or “power supply”).
- Probe both fuse test points to ground.
- If both sides have ~12V: go to Step 2.
- If only one side has ~12V: the fuse is open or not making contact. Replace/repair and investigate why it blew.
- If neither side has voltage: the fuse isn’t being fed (wrong key state, upstream feed issue). Trace upstream before blaming the relay or component.
Step 2 — Verify relay terminal 30 has power (contact feed)
- Remove the relay (if accessible) and identify terminal 30 in the socket using the diagram.
- Measure voltage from socket terminal 30 to ground.
- Expected: near battery voltage when the feed is present.
- If 0V at terminal 30: the issue is between fuse output and relay terminal 30 (open wire, poor terminal fit, corrosion in fuse box).
Step 3 — Verify the relay coil is being commanded (control power and ground)
Now confirm the relay is actually being told to turn on.
- Identify coil terminals 85 and 86 in the socket.
- With the component commanded ON, measure across 85 and 86 (red on one, black on the other).
- Expected: near battery voltage across the coil when commanded ON.
If you do NOT have voltage across the coil:
- Check for coil power: measure each coil terminal to ground; one should show ~12V (depending on design).
- Check for coil ground: the other should be near 0V when commanded ON (if ground-switched).
- If power is present but ground never appears (or vice versa), the problem is in the control side (switch/module output, interlock input, broken wire, poor ground for the module).
Step 4 — Verify relay output at terminal 87 (power leaving the relay)
- Reinstall the relay or use back-probing at the socket with the relay installed.
- Command ON and measure voltage from terminal 87 to ground.
- Expected: near battery voltage when energized.
Interpretation:
- If the relay clicks and coil command is correct but terminal 87 stays low: suspect relay contacts, wrong relay, wrong pin identification, or a missing feed at 30 under load.
- If terminal 87 shows ~12V but the component still isn’t powered: go to Step 5 (downstream wiring/load/ground).
Step 5 — Verify power at the component connector (load side)
Move to the component connector. Keep the black lead on a known good ground.
- Back-probe the component’s power pin (the wire coming from relay 87).
- Command ON and measure voltage to ground.
- If voltage is missing here but present at relay 87: there is an open/high resistance between relay and component (connector issue, broken wire, corrosion).
- If voltage is present here: the component is receiving power—now verify the ground path.
Step 6 — Verify the component ground (don’t assume it’s good)
A component can show “power present” but still not run if the ground is open or resistive.
Ground check method A: voltage at the ground pin
- Keep the circuit commanded ON.
- Place the red lead on the component’s ground pin, black lead on battery negative.
- Expected: near 0V. If you see several volts, the ground path is dropping voltage (bad ground connection, corroded splice, loose fastener).
Ground check method B: voltage drop from component ground to chassis ground
- Red lead on component ground pin.
- Black lead on a clean chassis ground near the component (or battery negative for a stricter test).
- Expected: very low voltage drop while the component is commanded ON. Higher readings indicate resistance in the ground path.
Common pitfalls in the “not powered” workflow
- Testing with the circuit OFF: many relay outputs only become live when commanded ON; verify the correct command state.
- Misidentifying relay pins: always use the relay case diagram/numbering; don’t rely on socket position guesses.
- Assuming a click means good output: always confirm terminal 87 voltage under command.
- Chasing the load before confirming the feed: start at fuse power-in/power-out, then relay 30, then coil command, then 87, then component, then ground.
- Backfeed readings: if a circuit shares loads/modules, you may see “ghost voltage.” Confirm by checking power on both sides of the fuse and verifying relay output with the circuit commanded ON.